Accessibility Reports & D1/AS1 Compliance New Zealand - ProjectX Management

Accessibility Reports & D1/AS1 Compliance Services

We specialise in comprehensive accessibility compliance assessments for both residential and commercial buildings. Our experienced team ensures your project meets D1/AS1 requirements and NZS 4121:2001 standards, creating inclusive environments that are accessible to all users.

"Our accessibility consultants combine technical expertise with practical council experience, ensuring your building design not only meets compliance requirements but also creates genuinely accessible and user-friendly spaces."

- ProjectX Management Accessibility Specialists

Accessibility compliance and building access solutions

Professional Accessibility Solutions

Expert compliance and inclusive design consulting

Understanding D1/AS1 & NZS 4121:2001 Compliance

D1/AS1 is the New Zealand Building Code Acceptable Solution for Access Routes, setting minimum requirements for safe and accessible movement through buildings. We work closely with architects and developers from the earliest design stages to ensure accessibility compliance is seamlessly integrated into your project.

NZS 4121:2001 provides the detailed technical specifications referenced by D1/AS1, covering everything from door widths and circulation spaces to accessible toilet facilities and parking requirements. Our expertise ensures your building meets both the regulatory pathway and the design standards.

Our comprehensive accessibility services include:

  • D1/AS1 compliance assessments and reports
  • NZS 4121:2001 technical specification reviews
  • Accessibility audits and gap analyses
  • Design recommendations and solutions
  • Council liaison and approval support
  • Ongoing compliance monitoring

D1/AS1 Requirements Coverage

We assess gradient and cross-fall limits for ramps, minimum clear widths for doors and corridors, threshold and surface requirements, and handrail specifications to ensure full compliance.

  • • Ramp gradients and cross-fall limits
  • • Door and corridor width requirements
  • • Threshold and surface specifications
  • • Handrail and stair compliance

NZS 4121:2001 Technical Detail

Our detailed assessments cover all technical specifications including accessible toilets, lift dimensions, parking spaces, signage requirements, and visual contrast standards.

  • • Accessible toilet and shower facilities
  • • Lift dimensions and control requirements
  • • Disabled parking space specifications
  • • Signage and tactile indicator standards

Our Comprehensive Accessibility Assessment Process

The result is more inclusive, compliant, and user-friendly buildings that serve all members of the community effectively. Our approach combines regulatory expertise with practical design solutions, ensuring your project achieves both legal compliance and genuine accessibility outcomes while maintaining design flexibility and cost-effectiveness.

Initial Assessment

Comprehensive review of building plans and designs against D1/AS1 and NZS 4121:2001 requirements, identifying compliance gaps and opportunities.

Detailed Analysis

Technical specification review covering access routes, door widths, ramp gradients, toilet facilities, lift requirements, and parking provisions.

Compliance Report

Comprehensive accessibility report with specific recommendations, design solutions, and clear pathways to achieve full compliance.

Accessibility Reports Frequently Asked Questions

What is D1/AS1 compliance and when do I need an accessibility report?

D1/AS1 is the New Zealand Building Code Acceptable Solution for Access Routes. You need an accessibility report when your building must comply with accessibility standards, including commercial buildings, public facilities, multi-unit residential developments, and buildings requiring disabled access compliance.

What is NZS 4121:2001 and how does it relate to D1/AS1?

NZS 4121:2001 is the New Zealand Standard for Design for Access and Mobility. It provides detailed technical specifications referenced by D1/AS1, including exact dimensions for door widths, circulation spaces, accessible toilets, lift requirements, and parking spaces for people with disabilities.

What types of buildings require accessibility compliance assessments?

Accessibility assessments are required for commercial buildings, public facilities, multi-story residential developments, educational institutions, healthcare facilities, retail spaces, and any building where public access or employee accommodation is required.

How can ProjectX help with accessibility compliance?

ProjectX provides comprehensive accessibility services including D1/AS1 compliance assessments, NZS 4121:2001 technical reviews, accessibility audits, design recommendations, council liaison, and ongoing compliance support throughout the building consent process.

What's included in an accessibility compliance report?

Our accessibility reports include detailed assessments of access routes, door widths, ramp gradients, handrail specifications, accessible toilet facilities, lift requirements, parking provisions, signage requirements, and recommendations for achieving full compliance.

How long does an accessibility assessment take to complete?

Accessibility assessment timelines vary by project complexity, typically ranging from 1-4 weeks. Simple residential projects may be completed faster, while complex commercial buildings with multiple accessibility requirements need more detailed analysis.

Can ProjectX assist with accessibility compliance outside Auckland?

Yes, ProjectX provides accessibility consulting services throughout New Zealand. Our experienced consultants understand regional council requirements and variations in accessibility standards across different territories.

Get Expert Accessibility Compliance Services

Contact us for professional accessibility reports, D1/AS1 compliance assessments, and NZS 4121:2001 consulting